PENGELOLAAN AIR BERSIH DI RS X SURABAYA

Authors

  • Zafira Maulidia Universitas Pembangunan Nasional “Veteran” Jawa Timur
  • Mohammad Mirwan 3Universitas Pembangunan Nasional “Veteran” Jawa Timur
  • Septin Aulidia Universitas Pembangunan Nasional “Veteran” Jawa Timur

Keywords:

Disinfection, Ultraviolet Lamp, and Clean Water Management

Abstract

To monitor, maintain, and maintain the quality of clean water in accordance with applicable regulations, optimal and effective management is needed. This research wants to look at the management of clean water which is intended to support facilities at the X Hospital in Surabaya. This study examines solutions to existing problems in clean water management. This research is intended to examine, analyze and understand the management of clean water at X Hospital Surabaya to answer the problem statement. Data were obtained from related hospitals, and various literature such as artivles and documents to access the latest data and information related to water distribution in clean water management at X Hospital Surabaya. In this study a solution to the problem of the clean water management system was obtained, namely replacing the use of chlorine in the desinfection process by using an ultraviolet lamp.

Downloads

Download data is not yet available.

References

Al Ajiz Hasbur, 2007. Monitoring Kualitas Air Minum Isi Ulang Di Sekitar Seturan dan Babarsari untuk Parameter Bakteriologis. Universitas Islam Indonesia. Yogyakarta.

Alaerts dan S.S. Santika. (1987). Metoda Penelitian Air. Surabaya: Usaha Nasional.

Bina Kesehatan Lingkungan, 2010. Air Bersih yang Sehat dengan Chlorine Diffuser.

Dirjen PPM & PL dan Dirjen Yanmed, 2002. Pedoman Sanitasi Rumah Sakit. Jakarta: Dep.Kes. R.I.

Djuhaeni, H. (2009). Penanggulangan Dampak Lingkungan Rumah Sakit. 8.

Muhajidah, Annisa Nurul. 2018. Perbedaan Lama Waktu Kontak Sinar Ultraviolet-C Terhadap Penurunan Jumlah Bakteri Escherichia Coli Pada Air Bersih di PT. Papyrus Sakti Paper Mill. Bandung: Poltekkes Kemenkes Bandung

Mulyatna, L., Rusmaya, D., Baehakhi, D. (2017). Hubungan Kebisingan dengan Persepsi Masyarakat di Ruang Rawat Inap Rumah Sakit Kelas A, Kelas B, dan Kelas C Kota Bandung. Journal of Community Based Environmental Engineering and Management, 1(1), 25-31. DOI: 10.23969/jcbeem.v1i1.1363

Ryani, Natasya. 2014. Pengaruh Lama Penyinaran Sinar Lampu Ultraviolet-C Terhadap Pertumbuhan Bakteri. Medan: Universitas Sumatera Utara

Said, I. N., dan Wahyono, D.H., “Teknologi Pengolahan Air Limbah Rumah Sakit dengan Teknik Biofilter Aerob-anaerob”. Jakarta: Direktorat Teknologi Lingkungan. Deputi Bidang Teknologi Informasi, Energi, Material dan Lingkungan-BPPT, 1999.

Said, Nusa Idaman. 2007. Disinfeksi Untuk Pengolahan Air Minum. Pusat Teknologi Lingkungan, BPPT

Setiawan, Fardi, dkk, 2010. Pengaruh Berbagai Jenis Senyawa Chlor terhadap Jumlah Residu Chlor pada Air Perusahan Daerah Air Minum (PDAM).

Wulansarie, Ria. 2012. Sinergi Teknologi Ozon dan Sinar Ultraviolet dalam Penyediaan Air Minum Sebagai Terobosan dalam Pencegahan Penyakit Infeksi Diare di Indonesia. Depok: Universitas Indonesia

Yuningsih, 2005.Pengaruh Cemaran Beberapa Senyawa Toksik Dalam Air Minum Terhadap Ternak. Balai Penelitian Veteriner, Wartazoa Vol. 15 No. 295-102.

Downloads

Published

2023-01-05

How to Cite

Zafira Maulidia, Mohammad Mirwan, & Septin Aulidia. (2023). PENGELOLAAN AIR BERSIH DI RS X SURABAYA. Nusantara Hasana Journal, 2(8), 36–41. Retrieved from https://nusantarahasanajournal.com/index.php/nhj/article/view/716